Make sure this part fits

Saturn 13500113 Relay

2007-2010 Saturn Outlook

Customer Questions & Expert Answers (4)
GM 13500113 Relay
  • Part Description
    RELAY, A/C Electrical
  • Replaces
    19116059, 88988889, 19116962
  • Manufacturer
    General Motors
Make sure this part fits
$7.74 MSRP: $14.60
You Save: $6.86 (47%)
Ships in 1-2 Business Days
1
ADD TO CART
  • Related Parts
  • Product Specifications
  • Vehicle Fitment
  • Customer Questions & Expert Answers
  • Product Specifications

    BrandGenuine Saturn
    Manufacturer Part Number13500113
    Part DescriptionRELAY, A/C Electrical
    Other NamesFan Relay, Fuel Pump Relay, Horn Relay
    Item Dimensions2.1 x 1.2 x 0.8 inches
    Item Weight0.30 Pounds
    ConditionNew
    Fitment TypeDirect Replacement
    Replaces19116059, 88988889, 19116962
    ManufacturerGeneral Motors
    SKU13500113
    WarrantyThis genuine GM part is guaranteed by GM's factory warranty.
    Shipping & ReturnShipping Policy Return Policy
    Warning: California’s Proposition 65
  • Vehicle Fitment

    Year Make Model Engine Important vehicle option details
    2007-2010 Saturn Outlook6 Cyl 3.6LSPORT UTILITY VEHICLE 2WD, SPORT UTILITY VEHICLE 4WD
  • Customer Questions & Expert Answers

    Q:
    I am wonder if this is complete and correct part for my vehicle. Posted by GMPartsGiant Specialist
    A:
    You can Select Your Vehicle to check if 13500113 fits your vehicle.
    Posted by GMPartsGiant Specialist
    Q:
    How to Test and Troubleshoot Relays for Buick Enclave,Chevrolet Traverse and GMC Acadia? Posted by Customer
    A:
    In the vehicle, various electrical accessories such as the fuel injection system, horns, starter, and fog lamps utilize relays to transmit electrical signals to their respective components. Relays work by using a low-current control circuit to open and close a high-current power circuit, enabling the proper operation of these components. Most relays can be found in the engine compartment and interior fuse/relay boxes. If a faulty relay is suspected, it can be tested using the following procedure or taken to a dealer service department or repair shop for evaluation. The relays used in these vehicles are typically ISO relays, adhering to International Standards Organization standards. They have numbered terminals indicating their circuit connections and functions. Two of the relay terminals are for the control circuit, connecting to the relay coil, while the other terminals serve as the power circuit. When energized, the relay's coil creates a magnetic field that closes the larger contacts of the power circuit, providing power to the circuit loads. Terminal 85 and 86 are usually the control circuit, with terminal 86 connected to battery positive (B+) voltage and terminal 85 to ground in relays with diode terminals. If the relay contains a resistor, terminals 85 and 86 can be connected in either direction with respect to B+ and ground. Terminal 30 is typically connected to the battery voltage source (B+) for the circuit loads, and terminal 87 is connected to the ground side of the circuit, either directly or through a load. Relays may have additional terminals, such as 87A, 87B, 87C, etc., for alternate load or ground connections. To test the relay, use an ohmmeter to check continuity through the relay control coil and ensure resistance matches the expected value. If the relay fails the tests or shows infinite resistance, it should be replaced. Additionally, when testing the relay's power circuit terminals, there should be no continuity between terminals 30 and 87 with the relay de-energized, but there should be continuity when the relay is energized using jumper wires. If any of the tests indicate a failure, the relay should be replaced.
    Posted by GMPartsGiant Specialist
    Q:
    How is the control circuit of a relay usually connected of the 2010 Buick Enclave? Posted by Customer
    A:
    In relays with diode terminals, terminal 85 and 86 are usually the control circuit, with terminal 86 connected to battery positive (B+) voltage and terminal 85 to ground.
    Posted by GMPartsGiant Specialist
    See expert answers on similar Relay
    Q:
    How are the power circuit and other additional terminals in a relay configured for the 2017 GMC Acadia? Posted by Customer
    A:
    Terminal 30 is typically connected to the battery voltage source (B+) for the circuit loads, and terminal 87 is connected to the ground side of the circuit. Relays may have additional terminals, such as 87A, 87B, 87C, etc., for alternate load or ground connections.
    Posted by GMPartsGiant Specialist
    See expert answers on similar Relay
    If you have any questions about this product, please don't hesitate to ask us. We will be happy to help you!

Genuine GM Part 13500113, the Right Choice

To ensure reliability, purchase GM part # 13500113 Relay. It is sometimes referred to as Saturn Relay, Saturn Daytime Running Light Relay, Saturn Headlight Relay. Directly from GM, genuine parts are superb with regards to quality, longevity, and fit. Every single part passed stringent quality testing, so you can be sure that it's safe, durable, and built to perform like your original parts. This part fits specific Saturn Outlook models.

GMPartsGiant.com is a leading supplier of genuine GM parts and accessories such as GM 13500113 Relay. You're certainly in the right place if you're searching for the great cost-effective OEM GM parts. Look no further than our vast inventory of genuine GM parts offered at unbeatable online prices, all of which are backed by the manufacturer's warranty. Not to forget, our hassle-free return policy and quick delivery service ensure a smooth shopping experience for you. For detailed Saturn parts information, click here.

Why choose GM Parts Giant

  • Dedicated Service

    Your complete satisfaction is our #1 goal

  • Lowest Prices

    Best deals on genuine OE parts from dealerships

  • Fast Delivery

    Orders are processed and delivered promptly